Tuesday, 29 May 2012

Glowworm Flexicom 15HX F1 Fault Lighting With A Bang

I was called to look at a Glowworm Flexicom 15HX which a customer was concerned about. The boiler was just over two years old and had been serviced six months ago. The boiler had occasionally been lighting with a bang for some time but not every time it lights. This was occuring prior to the service but the engineer was unable to establish a cause.

I checked the gas inlet pressure, and the combustion performance which were both perfect. I removed the electrode and there was slight distortion to the probes and some darkness to the tips. I replaced the electrodes and the boiler is lighting a lot better and the problem should hopefully be solved.


Disclaimer:
The works described in this blog are a record of work undertaken and should not be taken as guaranteed to solve your problem.

Work should only be carried out by persons qualified and competent to do so.

No comments:

Post a Comment