Monday 4 June 2012

Heating Coming On With The Hot Water

I had to look at a system where the heating was coming on with the hot water even though the heating was turned off and down. The system was a three-port motorised valve set up and had a Drayton MA1/679-3 valve. The valve was stuck in the middle position as I could see from indicator on the side. I removed the head from the valve body to see if the spindle had seized or it was a problem with the head. The spindle was free, but there was an unusual amount of rattling coming from the valve head. I opened the valve head and both the return springs were loose in the head. Both of the plastic lugs that the springs attached to had broken off also. I replaced the head of the valve and the system was working as it should be.


Disclaimer:
The works described in this blog are a record of work undertaken and should not be taken as guaranteed to solve your problem.

Work should only be carried out by persons qualified and competent to do so.

No comments:

Post a Comment